"@type": "ImageObject",
A wire inside the motor may be touching another wire, or the metal sides of the motor. Hi Joe, could be time, for new timer. I have a PF1112T. The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. Now The ice and snow have melted and the cover is getting in deeper. "dateModified": "1/10/2020",
Hey there! },
Check that dial is not warped. TO SET "ON" AND "OFF" TIMES: Hold trippers against edge of CLOCK-DIAL, pointing to time (AM or PM) when ON and OFF operations are desired, tighten tripper screws firmly. Other than a couple of weeks, we have spent fifteen years manually turning on our pump. Pull the timer out and turn it to the correct time. Then number(time of day) that you line up with the time marker will be the time that you are setting your timer to. If you cant, is the manual switch stuck or jammed? If your 120V wires are properly colored, the White wire connects to terminal A, and the Black wire connects to terminal 1. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Eldon, the breaker should not be bad, but the timeclock may be wired incorrectly. Proceed to step 4 to check the timer itself. I noticed that the on flipper was a little bit bent so I replaced it with new one. Sometimes the circuit breaker will trip again as soon as you reset it or even trip when the pump starts running. Hi Alfred, I would guess that either the time dial is bent, or that the larger gear behind the dial is missing a tooth, at 10 pm, or has a bit of grit stuck in the gear at that point. So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. That will do it. Check to be sure that the yellow time dial gear on the back is engaged with the connecting gear, and pushed all the way in. Make sure the middle time pointer is tight. I visually checked the clock motor and it was good. The tripper will not move. Also be careful not to loosen the timer pins to much or they could fall off the timer wheel and onto the ground. Welcome to Pool Spa Outpost! If the power has gone out, your just opening your swimming pool for the season or some third reason, you may need to adjust the time on your Intermatic swimming pool timer. Hi, I got the same problem as my clock not working. You may notice that the time pointer is loose or is moving around too much.If you find your pointer is loose, simply tighten the screw that holds the timer in place so that it doesnt wiggle around. Hi Agnes, have you tried using a cover pump to remove the rain and/or snow melt from the cover? Turn on / off manually work fine, but The clock gears still not moving. "wordCount": "1259",
For additional tripper pairs on CLOCK-DIALorder 156T1978A. Hello. If you are not sure if your timer is working or not you will first need to know if its even operational. I have the Intermatic T103 autotimer on my pool. As you release the dial, you will feel the gears engage. Any other thoughts? I have changed the dog tripper and that does not take care of - Answered by a verified Electrician . Slide it around the pool timer dial to the correct start time and re-tighten it. However the new breaker is in a constantly tripped position. my pool timer the does not turn itself on only shuts off I put new trips in but still not working I dont see any ant build up inside there or anything could it just be time to replace the old girl because thats what Im thinking. I currently manually turn it on and off. When the power goes out, the timer stops. But of the timer itself is bad you will need a licensed electrician to change the timer for you. Pool co says T104 timer needs replacement and filter cartridge. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
That way I could schedule the pump once again. Hi Fred, the only thought I have is that the cord should not be unplugged to turn off the pump, instead, rotate the dial until it turns off, because I dont believe there is a switch to turn off the timer. Step 3 Elite Swimming Pools TV 4.08K subscribers Subscribe 1.1K Share 97K views 3 years ago MIRAMAR Pool timer. The gears on my timer motor are clearly turning, but when the timer dog reaches the power-on lever, the switch wont flip. Back when I was a young technician I was taught to always look for the easy things and use all my senses. You can turn the dial and then only wait a few minutes to check is the OFF tab is working. Replace the gears if this is an issue. For any wiring concerns, always refer to the wiring diagram printed on the inside of the timer door. Put them back on and tighten them. It is a good idea to use pliers or a wrench and reseat the trippers, then tighten them at the desired on/off times. Not sure if i need to check out the wiring, but it is a bit frustrating. Any thoughts before I run out to replace it? Secure wire conduit to the knock out with the proper conduit connectors, and first connect the green ground wire to the green ground screw labeled GRD. It is a dayton time switch model 2E259 with switch rating of 40 amps, 2 HP, 250 volts AC with clock motor rating of 250 volts and 60 cycles. I copied the wiring config exactly and my clock gears still arent moving, so now Im thinking the wiring was wrong all along. Any advice? If there is still no movement, test the wires coming into the time clock to see if power is reaching the time clock. Thank you. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
If unsure, the White (Neutral) wire connects to the neutral buss bar in the breaker panel, and the Black (Line) wire would connect to the circuit breaker. Everythings OK now, unit works just fine. If so, is there power coming into the clock (on the line terminals)? Hi Bob, you have two blacks and one neutral? After this has been removed, you can turn the breaker back on and measure for the voltage on the timer input. If the trippers are set for on and off pump function and nothing is working, reset the time and trippers. http://waterheatertimer.org/Tork-timers-and-manuals.html Ill do the same. "logo": {
What was the fix?? My Intermatic Pool Timer still works like normal but, when it gets to the time set to turn pump on or off it doesnt. Did the power recently go out or has the circuit breaker tripped? Tighten them with a wrench. I have a 2 speed pump. Sound right? Timer not tripping pump on. Wont work manually or by timer function. No broken or loose wires visible. I just replaced my T101 timer 2 years ago. The problem was the connections I made inside my main electrical panel, I used romex wire nuts to attach the solid core #10 wire that I used to hook up the timer to the existing stranded #10 wire and it didnt make the connection so to speak. everything seems to be working correctly, but i can not turn the pump on or off by tripping the mechanism. "description": "Frequently asked questions about Intermatic T104 and T101 timeclocks, used to power many loads, and the primary timer used for swimming pool pumps in America. Hi Peter you say that clock is seated correctly, and I assume you mean that the dial is pushed in, or the gear on the back of the dial is engaged with the turning gear. However, after several hours, maybe overnight, the associated breaker will trip. Is there a separate switch somewhere between breaker and timer? but ythe costs for T104 models vary greatlyHave ahayward 1 1/2 horsepower pump inground pool in Fl. I replaced a bad timer (90% sure I put the wires in the correct/same spots but there was one time when two wires got loose, so its possible I wired it wrong) and now it turns on and works, but the on/off switch doesnt work. Terry, unusual but check all connections, making sure that bare wire is tightly contacting the terminal screw plates. If youre not sure which is the best timer for your pool to get, we have a full blogpost for which Intermatic timer you should get for your pool. 2. Watch these tips and tricks before replacing it. Started about a month ago and I checked the dog tripper at that time and it started working again for awhile but hasn't now for a week. Any suggestions? I tried to change the on tripper due to Daylight savings time & dropped the screw. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. how should I lubricate those? Pool timers can also be used to automatically turn on/off pool lights or other outdoor lighting around the pool. make sure it hasnt tripped and is switched on. GFCI breakers trip at a very low threshold, doesnt take much. What happened? Just installed a new timer. Hello. It just seems to have a weak start?? The trippers will "trip" the analog clock to turn on and off automatically at the set times. Is the timer repairable, or should I just install a new one? Donna Simpson Eating Website But What Toilet? Thanks for your help! If the pump doesnt come on, follow the steps below. Ive reset the time 5 times and just realized that its going counter clockwise. Second thing to check is the dial bent or warped, in that area where the on tripper is? "publisher": {
This product can be controlled with your voice through Alexa-enabled devices such as Amazon Echo and Amazon Tap. Can the pool timer be placed inside the garage to protect it from the harsh weather. My time clock has an ant infestation! The A terminal is not normally used, unless you have a 3 wire service. Timer dial is not turning Breaker OFF Turn ON Power Timer motor dead due to lightning Replace timer 3. I used to run the pump for 8-9 hrs a day. "caption": "In The Swim Blog"
Hello. Also be sure that the dial is not pulled out, but is engaging the gear behind the dial. What Im wanting to do is just disable the turn off/on and just keep power 24/7. The trippers can also get damaged. When I turned it back on now the pool clock goes backwards. Thanks for any help you can give. The trippers push on a tab on the on/off switch. I have heard that perhaps a run of mis-marked motors went out and you may have a 50 Hz actually. Spray WD-40 or any kind of lubricant onto the manual lever to loosen it. This page is fantastic!! You will have live wires exposed and they can kill you if you touch them. It sounds like the Line and Load wires are reversed. Hello, newer pool guy here. I have the PF1202T timer on my pool. Before using your timer to optimize your pump, you need to determine that your pool's pH, alkalinity, and calcium hardness are 7.4 to 7.6, 100 to 150 ppm, and 150 to 400 ppm, respectively. Any suggestions on how to troubleshoot? I had to order new trippers as mine have been straightened too many times. I turned the breaker off and back on and still not working. It should sit down nicely. "headline": "Intermatic Pool Timer Troubleshooting",
Once you remove the water, you can use your pool brush on a pole, to gently push the pillows back to the center. You can replace it but its really just easier to replace the entire mechanism. Ive got a weak pump battery so every time the mechanism shuts off it looses time. Because a pool timer is an electrical timer with mechanical aspects, the clock dial portion of the timer pulls out to set the time. Flip it from where it is now, to the opposite side. If you cant see an issue with the gears, then it could be the timer motor. Hi Cody, if you cannot see any obstruction in the motor gears, or any such mechanical issue, then I would assume an electrical issue, perhaps the wrong voltage for the clock. So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. David, check the wiring, the power in and power out wires may be reversed. Gas pool heaters are one of the best additions to a pool, but they are the most high-maintenance piece of equipment on, 22,000 pool parts in stock! Please advise. If you run rope/twine through the Air Pillow grommets, you can tie them to each other and run the rope/string to opposite sides of the pool, tying it off, so they will stay in the middle. Since it came out of the box today, it probably is not trash in the gears.It seems the plastic gears and/or the coil in the clock mechanism are not strong enough to engage the on/off points or not for long. Hello Davy, Terry here again. For some reason, whenever my timer hits the time its supposed to kick the pump on, it gets stuck at that time and the pump wont come on. It stays on until I turn off the circuit breaker. There are simply things you can do yourself like adjust the timer pins and set the clock on the timer. Terminal A (farthest to the left side) is not connected to anything. Advice? They are little ants that just came. During this the pump cannot be manually switched on. i would like to use a timer but am now afraid to try another. When you flip the switch does it separate and reconnect the tabs? Hi, new timer out of the box, 200V. Thank you so much. Hi, Davy, seeing lots of complaints here. We had a few power outages the last couple of weeks, but Ive reset the time and it continues to lose time. Reference Manual & Buyer's Guide Another Brick in the And does the switch look worn, where the tripper engages? Your email address will not be published. I have replaced the trippers, but the problem persists. Another thing you will need to troubleshoot and check is the circuit breaker for your pool timer. If the clock was already showing the correct time, check the On/Off Trippers (Pointers) are set to the correct time and are not loose. Hi Jeremy, I would try to pull the unit out and clean it well with compressed air and then spray with WD-40 and see if that helps. Generally, plug-in-outlet timer has gone bad, then it cannot be fixed. ), you should be able to discern if this is the problem, which could mean a new clock. A timer replacement would be required. In this post, we discuss a few quick and easy ways to troubleshoot your pumps Intermatic timer clock problems. Maybe 2/wks ago I replaced it with a new timer, and it's doing the same thing. Inspect the tripper portion, if it looks rounder or worn, replace them. PF1202T Freeze Protection Control Parts - INYOPools.com Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Free Shipping on all Orders over $49! So just turn the adjustment hold down screw on the timer pin counter clockwise about a full turn and then you will be able to slide the on or off pin to the right time on the timer wheel. Filter pump is ON at all timer Timer contacts welded Replace timer 5 . Karl, good question. Dont know what the issue is. I hope this helps. Check that the TEST button has not popped out. To check this, try to pull out the clock dial and then move it to the correct time and press it back down again. Grab it, pull it towards you, move it around then place it back down. Sometimes bugs get in there and jam the gears, sometimes debris is the issue and other times the gears get old and may lose a tooth. JACUSTOMER-hlvgjzll- : I have just sprayed WD-40 on the switch coils that move the lever that the trippers hit. Ill revise the scathing review I gave the unit on Amazon ratings to reflect the change. Why it always stop around 10pm by itself and not moving again? Hi Tom, sure you can spray some 3-in-1 or wd-40 on the motor gears, just depress the tab at 12 oclock and pop out the mechanism, to target the oil onto the gears. You off course will want to adjust one time pin at a time. If moving that is difficult, you could just avoid using the switch and turn the pump off with the timeclock instead, always keeping the switch on, and maybe taping the switch, to remind people not to use the switch. "@type": "ImageObject",
You dont have two OFF trippers, right? Be sure they are intact and are connected firmly on both ends, to the front terminals and to the motor on the reverse. At some time the timer was disconnected and the pump wired direct to the breakers. If I manually push the lever, it moves without much pressure. Much like your timer pointer, the trippers can become loose and move around as well. In most cases like this, replacing the trippers is the solution. "author": {
Luis, it will, until it is switched to OFF, or until the OFF tripper shuts it off. If it doesnt improve, inspect the contacts behind the time clock for insect infestation. A switch is easier to use, so you dont have to open the clock and stick wet fingers in there, and using the breaker is also less than desirable, as they can wear out faster if used as a switch. charging for timer($150.00) and filter cartridge replacement ($90.00) and a gasket($25.00)called bc of a hose leak, assume that is the gasket but then told that the other 2 parts are needed. "height": "219",
If not, that sounds like a weak/bad motor. Tighten down all brass screws securely, to hold all wires firmly in place. Hi Bev, seems legit to me! I didnt check the connections because it seemed like an ordeal to take the timer apart to get to the wiring and I didnt want to make matters worse. I fastened it very securely. After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? Now Im having to turn my pool pump on and off manually. Replace the plastic insulator cover, turn on the power, and observe the visual motor check. If it doesnt, there could be an issue with the clock face or gears. My pool cover is sinking into the pool because the two pillow have separated and have moved to the side. First you want to make sure there is actually power getting from the power board to the timer itself. See the wirig diagram in the owners manual here: https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf Clock motor power, as shown in the wiring diagram, comes from terminal 1 and also terminal 3. A 50 hz timer would run faster on 60 hz, but the housing of my replacement motor says 60 hz and it is the correct replacement model. This will cause issues such as the pump not switching on or off to the pump turning on or off at incorrect times. Copyright 2022 In The Swim. Hi Tanya, yes that sounds like it might be wired incorrectly, check the wiring diagram on the label, or if missing, you can find them online for your timer model. The most common pool timer used for inground pool pumps is the Intermatic time clock. Does the motor gradually start running slowly? Check the diagram on the box label, and connect the wires from the breaker to the terminals marked Line, and the wires that go to the pump connect to the terminals marked Load. Turn the metal bar until it contacts one of two plastic side tabs. Read Book Tork Trippers Manual Guide Pdf For Free Sea Kayaking The World Almanac Road Trippers' Guide to National Parks: 5,001 Things to Do, Learn, and See for Yourself Dream Trippers The Little Road Trip Handbook Technical Manual War Department Technical Manual Canadian Mining Journal. My Polaris booster pump ONLY turns on via the trippers. In this case its likely the On/Off trippers, loose wiring, the clock face not being located correctly or a faulty pump. (usually not). Start with the easy checks. That was probably what burned the plug. Intermatic timers are a great addition to your pool set up but they can go wrong. To inspect, shut off power at the breaker, and push on the clip at the top of the box, to allow the mechanism to fall forward, and then you can inspect the vertical copper bars, and see how they shift and come apart (or not), when the switch is turned to off. However, the timer will stop around 10pm everyday and will not continue moving forward again. We like that this pool timer because it is made from heavy-duty material and two grounded outlet makes it safe and durable. Power surges could be to blame. If not, Turn off breaker, release the mechanism with the tab on the inside top, to drop the mechanism forward. We had a storm last week and the yard flooded my pool so I went and switched the pool off at the breaker so it would not come on with the tabs until we were able to handle the pool. Hi Carlos, is there a GFCI outlet in the circuit? Beyond the savings you'll make on reduced running costs, you'll also prolong the lifespan of your . Hi Jerry, it could be that the lubricant is gone, or needs more lube on the switch. The screw in the center point timer occasionally comes loose due to vibrations from the pump and filter. I have an intermatic timer thats 2 years young. Look at the copper tabs on the back and observe the action as you flip the switch manually on and off. Assuming the wiring is all correct. The motor is running and I turn off using breaker in the electical box, I put a new timer in and does the same thing. Until it came in, I manually turned on and the tripper turned it off. To set it, you just move the on/off "trippers" where you want them. {
It worked for a day but the day after it didnt work. Home / Pool Repairs / Equipment Repairs / Intermatic Pool Timer Troubleshooting. I have a T104. These are the trippers that came with the time clock. If there has been a recent power outage, the clock will have stopped and youll need to reset the clock to the correct time. Check that the breaker is firmly pushed onto the bar, and is not loose. Grab your torch and shine it in the holes. "url": "https://intheswim.com/",
DEWENWILS Pool Pump Timer, Digital Timer Box, 2HP 40A 120-277 VAC, 7-Day 20 ON/Off Programmable Timer Switch for Water . Take a good look at the position of the pins and write down the locations. You can turn that yellow dial by hand CW to see if the trippers hit the off and on switch and to set the time on it. Hotels near Time Tripper, Arcueil on Tripadvisor: Find 9,014 traveller reviews, 1,228 candid photos, and prices for 2,893 hotels near Time Tripper in Arcueil, France. The timer not working is for the pump. "image": {
Are the gears engaged, in the center, behind the dial? Pool Timer Not Turning ON or OFF!! If I manually flip the switch nothing happens. With power off, you could also check the tightness of the on/off switch, it may be missing the tension spring also, check that its there. If you do have voltage either the timer isnt switching the power to the pump or theres an issue with the pump itself or the wiring between the pump and the timer. Should it still not work, I suspect a motor failure for the clock. Move the switch and see that they separate when off, and come together when on. . This site is owned and operated by AJH Trade Group. Does it need lubricant or something? The pointer should point straight down, and you pull out on the dial, to set the correct time, aligning the current time with the pointer. The tabs on the back of the timer may have fused together, or the tabs on the stationary switch at the rear of the motor, from a power surge. Voltage is 243, frequency is 60hz. Timer not tripping pump on. Wired correctly, #10 wire, nothing. Below is a breakdown of how to wire different Intermatic timer models. Did you find the issue? Hi there, Turn the power off at the breaker box and carefully remove the wires to the clock. by Intermatic Technical Support | Jul 25, 2022 Helpful? Timer must be reset for current time after power outage. "name": "In The Swim",
Is the dial bent or warped? After a power failure the timer clock can start up backwards, mine has done this several times. So if you see the 10am behind the time marker, this means that the timer has the current time of 10am. Hi Matthew T104 can only turn one pump on and off. If you have both pins take notice of there position and then come back in a few hours and see if they have changed from the spot they were in when you last looked. Also be sure that the ON dog is not actually an OFF dog, and that it is tightly secured to the dial edge and pushed all the way onto the dial, and straight. Keeping a pool operational is expensive enough anyway, so every saving you can make helps. The position of the metal bar forces the gear next to it to turn one way or another. It is an ON tripper right? I replaced the pump and still nothing is moving. Could also be grit or insects inside of the gears of the clock motor. "address": "",
(For outside light timer) The one before was original to the house & I had no trouble. Switch the breaker off at the power board. The timer appears to be working fine (keeps time). Pools are not cheap! by pool co. , so wondered about the cost. On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. $115 Providence distortion MIJ - $120 All working perfectly Should be clear in photos which include boxes, others will be bubble wrapped and . If the motor gears are not turning, check the wire tightness (Breaker off first), and depress the tab at top to inspect the rear of the mechanism, to see if anything looks funny back there. ft. 975 Telegraph Rd #103, Santa Paula, CA 93060 $409,000 MLS# V1-15365 Hillview Estates, where you own the land, and this one has a big lot, over 4,100. There is a second switch between the breaker and the timer. Monday the clock face was free spinning, today when I got home it had broken and fallen off. Now remove the terminal cover on the timer. Put a meter on the wires or trace them back to find out their voltage and source. This pool timer is waterproof, heavy-duty, and accurate. It would not reset itself and could not get power back to the timer. Hi Dave, my pool timers not working but when I look in the little window I do see the largest back gear turning (possibly the yellow time plate gear as that appears to be moving..yet not keeping correct time.) You most likely just need to now set the pins and the clock and your timer will work. I would shut off power to the clock while you spray, and release the tab at the top so you can spray behind the clock, and then find the nearby nest, and dig it up and add in some ant killer granular, or other method, to get the colony to move somewhere else. Intermatic timers can typically be fixed by checking theres power to the timer, resetting the time, renewing the ON/OFF trippers and renewing the gears or timer motor. And there you have it, the quick and easy ways to troubleshoot common Intermatic pool timer problems. Simply screw it back into place until its snug. Or be loose and not making good contact. Lately, the timer mechanism on my old T104R does not move. I went to my houses main panel breaker and Flipped that breaker which leads to the pool panel breaker and replaced that breaker which goes straight to the timer. IT happens, so I ask. I unscrewed the clip and put it back on and its still doing the same thing. 20 Reasons Why Pool Pumps Lose Pressure (and what to do), 25 Ways to Keep Ducks, Geese & Birds Out of Pool. Hi Casey, perhaps the cord or wires are broken? You can replace the entire mechanism or the gears. Pop-in a new timer mechanism, and replace the wires to the previous configuration. DEWENWILS Pool Pump Timer, Outdoor Smart Wi-Fi Box, Heavy Duty 40A 120-277 VAC 2HP Wireless Controller Timer for Pool, Water Heater, Compatible with Smart Phone, Alexa, Google Assistant, UL Listed. Is it Necessary? Date Listed: 18/02/2023; . If the motor or wires are faulty in your Intermatic time clock, its time to replace the mechanism.